KEW 3121A KEW 3122A KEW 3123A
DC Test Voltage 2500V 5000 V 5000V 10000V
Measuring Ranges
0∼2000MΩ/
1000∼100000MΩ
(automatic change)
0∼5000 MΩ/
2000∼ 200000MΩ
(automatic change)
0∼5GΩ/2∼200GΩ
(automatic change)
0∼10GΩ/4∼400GΩ
(automatic change)
Accuracy
Insulation
Resistance
±5% of reading
(100∼50000MΩ)
±10% of reading
or 0.5% of scale length
( ranges other than
listed above)
at
23℃ ±5℃
±5% of reading
(200∼ 100000MΩ)
±10% of reading
or 0.5% of scale length
( ranges other than
listed above)
at 23℃ ±5℃
±5% of reading
(0.2∼100GΩ)
±10% of reading
or 0.5% of scale length
( ranges other than
listed above)
at 23℃ ±5℃
±5% of reading
(0.4∼200GΩ)
±10% of reading
or 0.5% of scale length
( ranges other than
listed above)
at 23℃ ±5℃
±10% of reading
(100∼50000
MΩ)
±20% of reading
or 1.0% of scale length
( ranges other than
listed above)
at −10℃∼+40℃
±10% of reading
(200∼ 100000MΩ)
±20% of reading
or 1.0% of scale length
( ranges other than
listed above)
at −10℃ ∼+40℃
±10% of reading
(0.2∼100GΩ)
±20% of reading
or 1.0% of scale length
( ranges other than
listed above)
at −10℃∼+40℃
±10% of reading
(0.4∼200GΩ)
±20% of reading
or 1.0% of
scale length
( ranges other than
listed above)
at −10℃∼+40℃
Output
Voltage
2500V ±5%
(100∼50000MΩ)
5000V ±5%
(200∼ 100000MΩ)
5000V ±5%
(0.2~100GΩ)
10000V ±5%
(0.4~200GΩ)
Operating
Temperature & Humidity
−10℃ ∼+40℃ at 85% max. relative humidity
Storage
Temperature & Humidity
−20℃ ∼+60℃ at 90% max. relative humidity
Insulation Resistance 1000MΩ max./ 1000V between electrical circuit
& housing case
Withstand Voltage 5000V AC for one minute between electrical circuit & housing case
Dimensions 200(L)×140(W)×80(D)mm
Weight Approx. 1kg(including batteries)
Power Source 8 pcs of R6P (AA) battery or equivalent
Accessories
Hard Carrying Case:M-9158 Test Leads
(Line Probe:M-7165A,
Earth
Cord:M-7224A, Guard Cord:M-7225A)
Hard Carrying Case:M-9158 Batteries, Test Leads (Line
Probe:M-7165A, Earth Cord:M-7224A, Guard Cord:M-
7225A) Pickel type prod:M-8019
2. Specifications
Comments to this Manuals